仕様
英語の原文のまま載せます。
AC Power
- Line Voltage:120V, 60Hz
- Total Current Capacity:15 A
- UL1449 Suppression Rating:330V
- Protection Modes:L-N, L-G, N-G
- Initial Clamping Level:200V
- Energy Dissipation:1815 Joules
- Peak Impulse Current:73,000 Amps
- Catastrophic Surge Circuit:Yes
- Thermal Fusing:Yes
- Over-voltage shutoff:142 VAC ±5 VAC
- Under-voltage shutoff:90 VAC ±3VAC
- EMI/RFI Noise Filtration
- Banks 1 & 2:90 db, 100 KHz – 2 MHz
- Bank 3, High Current Outlets:60 db, 100 KHz – 2 MHz
DC Trigger Input
- Jacks:35mm (1/8”) mini-plug
- Voltage and Polarity:3 – 24V DC, bidirectional
- Current Requirement:46 mA @3V, 58 mA @24V
LAN Circuit
- Clamping Level:8V ± 2V
- Jacks:RJ-45
- Wires Protected:4-Wires, Pins 1, 2, 3 & 6
Telephone Circuit
- Fuseless/Auto-resetting:Yes
- Clamping Level:260V
- Capacitance:30pf (approx)
- Suppression Modes:Metallic & Longitudinal
- Jacks:RJ-11
- Wires Protected:2-Wire, Pins 4 & 5
Satellite TV Circuit
- Bidirectional:Yes
- Shielded:Yes
- Clamping Level:25V
- Attenuation:< 1db from 950MHz -205GHz
- < 24db @ 22GHz
- Connections:Female “F”, Gold Plated
Cable TV Circuit
- Bidirectional:Yes
- Shielded:Yes
- Clamping Level:14V
- Attenuation:< 1db up to 950MHz
- Connections:Female “F”, Gold Plated
※M5300-EXの英文マニュアルより引用
100Vで使えるか?関東で使えるか?
LAN、電話、衛星放送、ケーブルテレビの各種サーキットブレーカーを搭載しているようですが、使わないので割愛するとして、電源についても142V(±5V)を超えるか、90V(±5V)を下回ると電源が落ちて保護されるようですが、気になるのは入力電圧が120V/15A/60Hzという点ですね。
上記の90Vを下回ることがないので、100Vでも利用可能だと思いますが、関東(50Hz地域)で使って大丈夫なのかというのは懸念事項ではあります。とは違うので、多分入力された電気をそのままパススルーするのではないかと思いますが、不具合が起こる可能性もあります。
すでにこの製品はカタログからは消えていて、後継機はPanamax M5300-PMのようですが、海外ではこうしたシアター向けのパワーコンディショナーは複数のブランドが展開していて、検索するとAPCやFURMANなどの製品も出てくるんですが、120V仕様ということもあって日本では展開されていないんでしょうね。
とりあえず11個口のノイズフィルター電源タップ的な使い方ができれば、Power Plant Premierを取り外すことができるので、これを購入して試してみましょう。
パワーコンディショナーPANAMAX M5300-EX到着
100V/50Hzで動作するのか? 出水電器さんに依頼したオーディオ専用電源工事は日程調整中ですが、工事前と工事後の変化を数値として確認したいなと思うようになり、シアタールームの電源タップとして使用しているPS Audio Power Pl...